The NVFB-WB from Tenmat is a highly compressible, A1 rated stone wool cavity barrier designed for demanding external wall systems. Tested to BS EN 1366-4, it features a specific fibre orientation that enables effective sealing even where irregular outer surfaces are encountered, such as behind lapped cladding.
In the event of a fire, the NVFB-WB delivers non-ventilated, full-fill fire protection to restrict fire spread in external wall cavities. It offers up to 120 minutes of integrity and insulation, and is suitable for a variety of applications including timber SIPS panels, masonry with DPC membranes, and both lapped and flat weatherboard cladding.
Fire Rating (Reaction to Fire): A1(Non-combustible)
Fire Protection (Resistance to Fire): 120minutes
Tenmat FF102/50 Ventilated Cavity Fire Barrier is manufactured from a low smoke zero halogen high expansion intumescent material and covered with aluminium foil, for use horizontally within uninsulated, ventilated and drained cavities, up to 50mm wide. It allows maximum ventilation and drainage of cavities reducing the need for cavity trays or weepholes. Tenmat FF102/50 Ventilated Cavity Fire Barrier can be easily and quickly installed and no maintenance required after installation.
Lightweight, easy to install,
No maintenance required after installation,
Suitable for open-state ventilated cavities up to 50mm wide,
Fire Rated for up to 120 minutes,
Working life 60 years,
Can be used in conditions exposed to weather (UV, rain, frost)
For use horizontally within uninsulated, ventilated and drained cavities, up to 50mm wide.
A clear impregnation solution designed to prevent the spread of fire on solid timber.
Classified to BS EN 13501-1:2018
Achieves European Class B-s2,d0
For internal and external use
Waterborne
Colourless and virtually odourless
Tested by BTTG, reference number: 27/05662A/07/21
Use
Zeroflame Treatment has been successfully tested to BS EN 13501, achieving B-s2,d0 on solid wood with a minimum thickness of 12mm and density of 400kg/m³.
Appearance & Overcoating
Zeroflame Treatment leaves no visible finish, achieving a natural appearance. Zeroflame Treatment should not be overcoated. Application of any product over Zeroflame Treatment may adversely affect the fire protection performance.
A clear impregnation solution designed to prevent the spread of fire on solid timber.
Classified to BS EN 13501-1:2018
Achieves European Class B-s2,d0
For internal and external use
Waterborne
Colourless and virtually odourless
Tested by BTTG, reference number: 27/05662A/07/21
Use
Zeroflame Treatment has been successfully tested to BS EN 13501, achieving B-s2,d0 on solid wood with a minimum thickness of 12mm and density of 400kg/m³.
Appearance & Overcoating
Zeroflame Treatment leaves no visible finish, achieving a natural appearance. Zeroflame Treatment should not be overcoated. Application of any product over Zeroflame Treatment may adversely affect the fire protection performance.
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional
Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes.The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.